Huiyao Capacity Calculator

Estimate theoretical and OEE-adjusted annual battery line capacity.

Should I use this

Quality & Safety

A
Description quality
100%
Schema completeness
100%
Naming quality
80%
Poisoning risk
100%
Permission match
100%
Protocol compliance
100%

Findings (1)

  • LOWTool 'calculate_battery_line_capacity' name length outside 3-30 rangein calculate_battery_line_capacity

Based on automated analysis of tool definitions and protocol compliance.

Context Cost

~1,027Tokens (tool definitions)
~11.8 KBTypical response size
Moderate attention impact (0.80% of 128k context)

This is the approximate number of tokens consumed each time the server's tools are loaded into a model's context. Higher counts reduce the attention available for other tasks.

Install

One-Click Install

Add this to your `claude_desktop_config.json` file:

{
  "mcpServers": {
    "capacity-calculator": {
      "url": "https://huiyao-capacity-calculator-mcp.hy-208.workers.dev/mcp"
    }
  }
}

Remote endpoints

https://huiyao-capacity-calculator-mcp.hy-208.workers.dev/mcpstreamable-http

What it can do

Tool inventory

Tools (1)

🟢 Read-only🟡 Write🔴 Delete⚪ Unknown
🟢calculate_battery_line_capacity(throughput_cells_per_minute, shifts_per_day, hours_per_shift, operating_days_per_year, oee_percent, ...)

Estimate theoretical and OEE-adjusted annual battery-cell and energy output from line throughput, schedule, OEE, nominal cell voltage, and nominal cell capacity. Use for early production-line sizing and scenario checks; results are engineering estimates, not guaranteed output.

Input Schema

{
  "type": "object",
  "properties": {
    "throughput_cells_per_minute": {
      "type": "number",
      "exclusiveMinimum": 0,
      "maximum": 10000,
      "description": "Steady-state cell throughput in cells per minute."
    },
    "shifts_per_day": {
      "type": "integer",
      "minimum": 1,
      "maximum": 4,
      "description": "Number of scheduled production shifts per day."
    },
    "hours_per_shift": {
      "type": "number",
      "exclusiveMinimum": 0,
      "maximum": 24,
      "description": "Scheduled hours in each shift."
    },
    "operating_days_per_year": {
      "type": "integer",
      "minimum": 1,
      "maximum": 366,
      "description": "Scheduled operating days per year."
    },
    "oee_percent": {
      "type": "number",
      "minimum": 0,
      "maximum": 100,
      "description": "Overall equipment effectiveness as a percentage from 0 to 100."
    },
    "cell_voltage_v": {
      "type": "number",
      "exclusiveMinimum": 0,
      "maximum": 20,
      "description": "Nominal voltage of one cell in volts."
    },
    "cell_capacity_ah": {
      "type": "number",
      "exclusiveMinimum": 0,
      "maximum": 10000,
      "description": "Nominal capacity of one cell in ampere-hours."
    }
  },
  "required": [
    "throughput_cells_per_minute",
    "shifts_per_day",
    "hours_per_shift",
    "operating_days_per_year",
    "oee_percent",
    "cell_voltage_v",
    "cell_capacity_ah"
  ],
  "$schema": "https://json-schema.org/draft/2020-12/schema"
}

Output Schema

{
  "type": "object",
  "properties": {
    "formula_version": {
      "type": "string"
    },
    "inputs": {
      "type": "object",
      "properties": {
        "throughput_cells_per_minute": {
          "type": "number",
          "exclusiveMinimum": 0,
          "maximum": 10000,
          "description": "Steady-state cell throughput in cells per minute."
        },
        "shifts_per_day": {
          "type": "integer",
          "minimum": 1,
          "maximum": 4,
          "description": "Number of scheduled production shifts per day."
        },
        "hours_per_shift": {
          "type": "number",
          "exclusiveMinimum": 0,
          "maximum": 24,
          "description": "Scheduled hours in each shift."
        },
        "operating_days_per_year": {
          "type": "integer",
          "minimum": 1,
          "maximum": 366,
          "description": "Scheduled operating days per year."
        },
        "oee_percent": {
          "type": "number",
          "minimum": 0,
          "maximum": 100,
          "description": "Overall equipment effectiveness as a percentage from 0 to 100."
        },
        "cell_voltage_v": {
          "type": "number",
          "exclusiveMinimum": 0,
          "maximum": 20,
          "description": "Nominal voltage of one cell in volts."
        },
        "cell_capacity_ah": {
          "type": "number",
          "exclusiveMinimum": 0,
          "maximum": 10000,
          "description": "Nominal capacity of one cell in ampere-hours."
        }
      },
      "required": [
        "throughput_cells_per_minute",
        "shifts_per_day",
        "hours_per_shift",
        "operating_days_per_year",
        "oee_percent",
        "cell_voltage_v",
        "cell_capacity_ah"
      ],
      "additionalProperties": false
    },
    "run_time": {
      "type": "object",
      "properties": {
        "theoretical_hours_per_year": {
          "type": "number"
        },
        "oee_adjusted_hours_per_year": {
          "type": "number"
        }
      },
      "required": [
        "theoretical_hours_per_year",
        "oee_adjusted_hours_per_year"
      ],
      "additionalProperties": false
    },
    "cell_output": {
      "type": "object",
      "properties": {
        "theoretical_cells_per_year": {
          "type": "number"
        },
        "oee_adjusted_cells_per_year": {
          "type": "number"
        }
      },
      "required": [
        "theoretical_cells_per_year",
        "oee_adjusted_cells_per_year"
      ],
      "additionalProperties": false
    },
    "energy_output": {
      "type": "object",
      "properties": {
        "theoretical_mwh_per_year": {
          "type": "number"
        },
        "theoretical_gwh_per_year": {
          "type": "number"
        },
        "oee_adjusted_mwh_per_year": {
          "type": "number"
        },
        "oee_adjusted_gwh_per_year": {
          "type": "number"
        }
      },
      "required": [
        "theoretical_mwh_per_year",
        "theoretical_gwh_per_year",
        "oee_adjusted_mwh_per_year",
        "oee_adjusted_gwh_per_year"
      ],
      "additionalProperties": false
    },
    "assumptions": {
      "type": "array",
      "items": {
        "type": "string"
      }
    },
    "formula": {
      "type": "object",
      "properties": {
        "theoretical_cells_per_year": {
          "type": "string"
        },
        "oee_adjusted_cells_per_year": {
          "type": "string"
        },
        "oee_adjusted_energy_wh_per_year": {
          "type": "string"
        }
      },
      "required": [
        "theoretical_cells_per_year",
        "oee_adjusted_cells_per_year",
        "oee_adjusted_energy_wh_per_year"
      ],
      "additionalProperties": false
    },
    "links": {
      "type": "object",
      "properties": {
        "official_calculator": {
          "type": "string",
          "format": "uri"
        },
        "engineering_contact": {
          "type": "string",
          "format": "uri"
        }
      },
      "required": [
        "official_calculator",
        "engineering_contact"
      ],
      "additionalProperties": false
    }
  },
  "required": [
    "formula_version",
    "inputs",
    "run_time",
    "cell_output",
    "energy_output",
    "assumptions",
    "formula",
    "links"
  ],
  "$schema": "https://json-schema.org/draft/2020-12/schema",
  "additionalProperties": false
}

Community

Rate this Server

Evidence

Recent observations

verifiedversion not recorded1 tools