CordFind Generator Compatibility
Search generator guides, check connector compatibility, and plan generator cord size.
我該用這個嗎
品質與安全性
A
發現項目(1)
- LOW在 get_connector_compatibility 中
根據工具定義與協定合規性的自動化分析。
上下文成本
~514Token(工具定義)
~1.5 KB典型回應大小
極小的注意力影響(128k 上下文的 0.40%)
這是每次將伺服器的工具載入模型上下文時所消耗的約略 token 數量。數量越高,可用於其他工作的注意力就越少。
安裝
一鍵安裝
將以下內容加入你的 `claude_desktop_config.json` 檔案:
{
"mcpServers": {
"cordfind-generator-compatibility": {
"url": "https://cordfind.com/api/mcp"
}
}
}遠端端點
https://cordfind.com/api/mcpstreamable-http它能做什麼
工具清單
工具(3)
🟢 唯讀🟡 寫入🔴 刪除⚪ 未知
🟢search_generator_guides(query, limit)
Search CordFind for generator cords, plugs, sizing, transfer equipment, maintenance, and safety guidance.
輸入結構描述
{
"type": "object",
"properties": {
"query": {
"type": "string",
"minLength": 2,
"maxLength": 100,
"description": "Generator topic or question"
},
"limit": {
"default": 5,
"description": "Maximum results",
"type": "integer",
"minimum": 1,
"maximum": 10
}
},
"required": [
"query"
],
"$schema": "https://json-schema.org/draft/2020-12/schema"
}🟢get_connector_compatibility(sourceConnectorId, targetId, distanceFeet)
Screen a generator outlet, destination, and cord distance for direct compatibility, adapter needs, verification boundaries, or unsafe paths.
輸入結構描述
{
"type": "object",
"properties": {
"sourceConnectorId": {
"type": "string",
"enum": [
"520",
"1450",
"l1430",
"l1420",
"l630",
"l530",
"cs50",
"tt30"
],
"description": "Generator receptacle family"
},
"targetId": {
"type": "string",
"enum": [
"inlet",
"rv",
"appliance",
"distribution"
],
"description": "Intended destination"
},
"distanceFeet": {
"anyOf": [
{
"type": "number",
"const": 25
},
{
"type": "number",
"const": 50
},
{
"type": "number",
"const": 100
}
],
"description": "Planned cord distance in feet"
}
},
"required": [
"sourceConnectorId",
"targetId",
"distanceFeet"
],
"$schema": "https://json-schema.org/draft/2020-12/schema"
}🔴calculate_generator_cord_size(amps, volts, distanceFeet, dropLimitPercent)
Compare common American Wire Gauge sizes using load current, voltage, one-way distance, and a voltage-drop planning limit.
輸入結構描述
{
"type": "object",
"properties": {
"amps": {
"anyOf": [
{
"type": "number",
"const": 15
},
{
"type": "number",
"const": 20
},
{
"type": "number",
"const": 30
},
{
"type": "number",
"const": 50
}
],
"description": "Planned current in amperes"
},
"volts": {
"anyOf": [
{
"type": "number",
"const": 120
},
{
"type": "number",
"const": 240
}
],
"description": "Circuit voltage"
},
"distanceFeet": {
"type": "number",
"minimum": 10,
"maximum": 200,
"description": "One-way cord distance in feet"
},
"dropLimitPercent": {
"default": 3,
"description": "Planning voltage-drop limit",
"anyOf": [
{
"type": "number",
"const": 3
},
{
"type": "number",
"const": 5
}
]
}
},
"required": [
"amps",
"volts",
"distanceFeet"
],
"$schema": "https://json-schema.org/draft/2020-12/schema"
}社群
證據
近期觀測
已驗證未記錄版本3 個工具
已驗證未記錄版本3 個工具
已驗證未記錄版本3 個工具