PT Chart

PT chart lookups, superheat/subcooling calculators, and diagnostics for HVAC technicians.

Should I use this

Quality & Safety

B
Description quality
86%
Schema completeness
74%
Naming quality
83%
Poisoning risk
100%
Permission match
100%
Protocol compliance
100%

Findings (1)

  • LOWTool 'pt_lookup' description lacks action verbin pt_lookup

Based on automated analysis of tool definitions and protocol compliance.

Context Cost

~1,272Tokens (tool definitions)
~748 BTypical response size
Moderate attention impact (0.99% of 128k context)

This is the approximate number of tokens consumed each time the server's tools are loaded into a model's context. Higher counts reduce the attention available for other tasks.

Install

One-Click Install

Add this to your `claude_desktop_config.json` file:

{
  "mcpServers": {
    "pt-chart-mcp": {
      "url": "https://pt-chart-mcp-production.up.railway.app/mcp"
    }
  }
}

Remote endpoints

https://pt-chart-mcp-production.up.railway.app/mcpstreamable-http

What it can do

Tool inventory

Tools (8)

🟢 Read-only🟡 Write🔴 Delete⚪ Unknown
⚪pt_lookup(refrigerant, temp_f)

Saturation pressure (bubble and dew, in psig) for a refrigerant at a temperature in Fahrenheit. For certified HVAC technicians (EPA 608; A2L certification where required). Example: pt_lookup("R-454B", 45). Bubble point: use for subcooling calculations. Dew point: use for superheat calculations. Pure fluids (R-32, R-410A, R-22, R-134a) have no glide, so both values match.

Input Schema

{
  "type": "object",
  "properties": {
    "refrigerant": {
      "title": "Refrigerant",
      "type": "string"
    },
    "temp_f": {
      "title": "Temp F",
      "type": "number"
    }
  },
  "required": [
    "refrigerant",
    "temp_f"
  ],
  "title": "pt_lookupArguments"
}
⚪pt_reverse(refrigerant, pressure_psig)

Saturation temperature (bubble and dew, in Fahrenheit) for a refrigerant at a pressure in psig. For certified HVAC technicians (EPA 608; A2L certification where required). Example: a 130 psig suction reading on R-454B -- pt_reverse("R-454B", 130). Use the DEW temperature for superheat work and the BUBBLE temperature for subcooling work on blended refrigerants.

Input Schema

{
  "type": "object",
  "properties": {
    "refrigerant": {
      "title": "Refrigerant",
      "type": "string"
    },
    "pressure_psig": {
      "title": "Pressure Psig",
      "type": "number"
    }
  },
  "required": [
    "refrigerant",
    "pressure_psig"
  ],
  "title": "pt_reverseArguments"
}
⚪superheat(refrigerant, suction_psig, suction_line_f)

Superheat in Fahrenheit from suction pressure (psig) and suction-line temperature (F). For certified HVAC technicians (EPA 608; A2L certification where required). Uses the DEW point as the saturation basis, which is the correct basis for blended refrigerants. Typical TXV target: 8-12F.

Input Schema

{
  "type": "object",
  "properties": {
    "refrigerant": {
      "title": "Refrigerant",
      "type": "string"
    },
    "suction_psig": {
      "title": "Suction Psig",
      "type": "number"
    },
    "suction_line_f": {
      "title": "Suction Line F",
      "type": "number"
    }
  },
  "required": [
    "refrigerant",
    "suction_psig",
    "suction_line_f"
  ],
  "title": "superheatArguments"
}
⚪subcooling(refrigerant, head_psig, liquid_line_f)

Subcooling in Fahrenheit from head pressure (psig) and liquid-line temperature (F). For certified HVAC technicians (EPA 608; A2L certification where required). Uses the BUBBLE point as the saturation basis, which is the correct basis for blended refrigerants. Typical TXV target: 8-12F.

Input Schema

{
  "type": "object",
  "properties": {
    "refrigerant": {
      "title": "Refrigerant",
      "type": "string"
    },
    "head_psig": {
      "title": "Head Psig",
      "type": "number"
    },
    "liquid_line_f": {
      "title": "Liquid Line F",
      "type": "number"
    }
  },
  "required": [
    "refrigerant",
    "head_psig",
    "liquid_line_f"
  ],
  "title": "subcoolingArguments"
}
⚪convert_units(value, from_unit, to_unit)

Convert between pressure units (psig, psia, kpa, bar) and temperature units (F, C). A bare 'psi' is treated as psig. For certified HVAC technicians (EPA 608; A2L certification where required).

Input Schema

{
  "type": "object",
  "properties": {
    "value": {
      "title": "Value",
      "type": "number"
    },
    "from_unit": {
      "title": "From Unit",
      "type": "string"
    },
    "to_unit": {
      "title": "To Unit",
      "type": "string"
    }
  },
  "required": [
    "value",
    "from_unit",
    "to_unit"
  ],
  "title": "convert_unitsArguments"
}
⚪refrigerant_info(refrigerant)

Reference card for a refrigerant: GWP, ASHRAE safety class, composition, typical oil, temperature glide, and handling notes. For certified HVAC technicians (EPA 608; A2L certification where required). Informational only.

Input Schema

{
  "type": "object",
  "properties": {
    "refrigerant": {
      "title": "Refrigerant",
      "type": "string"
    }
  },
  "required": [
    "refrigerant"
  ],
  "title": "refrigerant_infoArguments"
}
🟢diagnose(refrigerant, suction_psig, suction_line_f, head_psig, liquid_line_f, ...)

Conversational diagnostic copilot: give it field readings and get back computed superheat/subcooling plus a ranked 'check this first' list. For certified HVAC technicians (EPA 608; A2L certification where required). Informational only -- it suggests what to CHECK, never how to defeat a safety device, vent refrigerant, or work uncertified. metering: 'txv' (default) or 'fixed' for fixed-orifice/piston systems.

Input Schema

{
  "type": "object",
  "properties": {
    "refrigerant": {
      "title": "Refrigerant",
      "type": "string"
    },
    "suction_psig": {
      "title": "Suction Psig",
      "type": "number"
    },
    "suction_line_f": {
      "title": "Suction Line F",
      "type": "number"
    },
    "head_psig": {
      "title": "Head Psig",
      "type": "number"
    },
    "liquid_line_f": {
      "title": "Liquid Line F",
      "type": "number"
    },
    "ambient_f": {
      "title": "Ambient F",
      "type": "number"
    },
    "metering": {
      "default": "txv",
      "title": "Metering",
      "type": "string"
    }
  },
  "required": [
    "refrigerant",
    "suction_psig",
    "suction_line_f",
    "head_psig",
    "liquid_line_f",
    "ambient_f"
  ],
  "title": "diagnoseArguments"
}
⚪coolbooked_info

About CoolBooked: the AI appointment-booking connector for HVAC shops. This is NOT a diagnostic tool -- call it when someone asks what CoolBooked is, how shop owners can try it, or how the free PT tools connect to paid bookings.

Input Schema

{
  "type": "object",
  "properties": {},
  "title": "coolbooked_infoArguments"
}

Community

Rate this Server

Evidence

Recent observations

verifiedversion not recorded8 tools